Power as a new green lighting white LED light conversion technology, high efficiency, low energy consumption, long life, no maintenance etc, were gradually applied in all kinds of lighting field. The LED long life is based on its safe working environment, for the LED illumination speaking, there are two major kinds of threat affect its life expectancy: one is the CLP impact, is imposed on current exceeds LED the LED technology databooks maximum rated current, including over-voltage cause CLP impact; Another kind is overheating damage. The damage can be represented as a failure of the device, can also occur immediately after the over-current impact event only failure, shorten long working life LED.
The cause of damage LED lamps and lanterns
LED lamps and lanterns is from power and failure a failure, 2 it is driven from the failure of LED device itself. Usually LED power and drive damage from the input voltage to the CLP impact (EOS) the breakers and the load fault. Input voltage to the CLP impact often causes driving circuit drive chip in the damage, and capacitance etc passive components happen breakdown damage. Load caused by the fault of the may drive circuit, drive circuit over current drivers may have short-circuited damage or have to short-circuit fault overheating damage. The failure of LED device itself basically has the following kinds of situations.
1. Transient flow events
Transient flow incident is more than the current flows through the LED the largest LED technology data handbook rated current, this may be due to the large current directly produce may also is made from high voltage indirectly from, such as transient lightning, switch power of transient switch noise, power grid fluctuation etc, over-voltage event that caused over-current. These events are transient, last time is very short, we usually call it the rush, such as "current peak", "voltage rush". Cause transient flow events were also includes LED switch on the power, or a charged when inserted the transient over-current.
The LED lighting, for a car ISO7637-2 of transient cast load surge impact is its normal work a important threat.
The impact of LED suffer CLP failure mode is not fixed, but usually cause welding wire damage, as shown in figure 1 below. This damage usually consists of great transient over-current cause. In addition to causing welding line break outside, still burn could lead to other parts of the welding line near the damage, such as sealing material.
Figure 1: LED the welding burn broken damage.
2. Electrostatic discharge events
Electrostatic discharge (ESD) damage is the high level of integration semiconductor manufacturing, transportation and the application of the most common kind of transient over-voltage harm, and LED tube lighting system is required to meet IEC61000-4-2 standard "body of electrostatic discharge model", to prevent 8kV contact discharge in electrostatic discharge system has may lead to failure of the CLP impact.
LED PN junction array performance will appear to reduce or damaged, as shown in figure 2. ESD events to discharge path LED chips internal failure, this failure may be just local function damage, serious word can also cause permanent damage LED.
Figure 2: LED part PN junction damage.
For nearly 80 percent of all energy into heat LED bulb lighting design character, thermal management and fault overheating protection is its face challenge. Theory and practice have proved that the performance and life is LED the PN junction with LED temperature closely related work. When LED chips ℃ high temperature within 10 knots, flux will attenuation 1%, LED life will be reduced by 50%.
Power supply and power circuit protection
Because the LED power and drive circuit vulnerable to CLP impact and short-circuit fault and damage, so in driving circuit design should fully consider various fault state protection measures in order to improve the reliability of the circuit, thereby reducing FanXiuLv. Tyco electronics LVR series of PTC can realize the ac power over-current and short circuit protection, the ROV used for CLP impact and surge protection. POLYZEN series is used in the dc power input port of over-voltage over-current comprehensive protection components, LED lamp string is the surface sticks series realize the load flow or breaker failure protection (figure 3).
Figure 3: LED lamps and lanterns power and drive circuit protection design.
PPTC in LED lighting of flow and overheating protection
Although many high-end LED drive device gradually integrated overcurrent protection functions such as, overheating, but in many places, especially overheating protection, still need division components scheme as protection scheme to make coordinated with higher reliability and lamps and lanterns more long life.
PPTC refers to polymer is temperature thermistors, is made with conductive polymer nanoparticles with special structure, processing, conductive polymer particles in the conductive pathways constitute chains. When normal working current through the (or components in normal environment temperature), PPTC show low resistance state. When circuit has anomalous over-current through (or environmental temperature), large current (or environmental temperature) generated heat make polymer rapid expansion, cut conductive particles PPTC conductive pathways, a high impedance condition. When circuit over-current (overtemperature condition) exclusion, polymer cooling, volume resume normal again, including conductive particles PPTC and constitutes a conductive pathways, a initial low resistance state. PPTC small in size, low cost, can use repeatedly, realized the circuit protection the automatic start and automatic recovery.
In LED lighting, according to the different application situation of lamps and lanterns has different overheating protection way, usually divided into two kinds. One way is to immediately start shut off the specified temperature protection (figure 4), such protection, usually applied in road traffic lights. Another way is to a certain temperature to drop, start-up protection current drivers (FIG. 5), such protection, usually used in indoor lighting and road lighting.
Figure 4: tyco LVR series products used for exchange LED lighting system over-current, thermal shutoff protection.
Graph 5: tyco LVR series products used for exchange LED lighting system over-current, temperature drop current protection.
Tyco electronics in LED spotlight lighting applications development, a new PolySwitch products. This product under 65 ℃ in the environmental temperature can ensure the normal through 350mA current environmental temperature, available in more than 85 ℃ for protection when, through the reasonable design, configuration, can respectively to shut off or dim way towards the LED lamps and lanterns to protect.
Combining parallel giant array lighting or landscape lamp over-current and over-heat protection in the cost and protection scheme in the mutual balance, usually have two protection scheme can use. One is dropping protection (FIG. 6) : to string together LED system, can be in every branch PPTC respectively on a single series of protection. This way the benefits can be achieve precise protection, not because a branch failures causing the lamps and lanterns of the reliability of work to protect. 2 it is thingseses protection (figure 7) : this kind of protection is the main way back in the lamps and lanterns PPTC series a star on the entire lamps and lanterns to protect. This way is low cost, the benefits of ouija area small.
Figure 6: LED array protection scheme. Shunts
Figure 7: LED array thingseses protection scheme.
In addition, PPTC can serve as temperature sensor is used together with LED drive, to realize the array illuminators LED overheating protection (FIG 8), in the large array lighting, LED lamp because of numerous and complicated structure, easy to appear in actual application of overheating fault location, often not fixed in a particular position, therefore single overheating detection device is difficult to provide perfect overheating protection. During normal working PPTC under low resistance and is the temperature coefficient characteristics, can conveniently PPTC series several orbiters in thermal protection detection circuit, achieve more overheat monitoring. Will more PPTC series, and installed in May overheat parts. Due to the low resistance, PPTC THRM pins level 0, power circuit work normally. When lamps and lanterns somewhere or more points happened when THRM temperature fault, a single or a few loops of PPTC heated, resistance star has risen sharply. THRM pins into high level, and level of the start-up LED drive design overheating protection plan, realize overheat shut off or overheating fold minus drive. This solution of the area light to LED overheating protection speaking economic and effective. Tyco electronics can provide related design and certification services.
Figure 8: overheating protection scheme PPTC much hot achieved.
This paper summaries
PPTC because of its own many characteristics, which is very suitable for LED par light lighting system over-current and over-heat protection in the design, can be installed in the metal core PTC boards or LED to achieve the best cooling plate heat transfer, make PPTC protection more timely and effective. In addition, PPTC product packaging diverse forms, can according to the customer request custom encapsulation, flexibility is very strong. But overheating protection no standard solutions, specific design must be combined with actual lamps and lanterns, and fully and validation. Tyco electronics, with the engineers to according to the actual situation of the research solutions, reduce the LED lighting system failure and maintenance costs.